Anodyne Therapy® Model 480 PRO™

Model 480_Pro

The Anodyne Therapy® Model 480 PRO™ is a professional, noninvasive infrared light therapy system designed for use by healthcare providers in clinical settings. It delivers Monochromatic Infrared Energy (MIRE™) at 890 nm through flexible therapy pads containing infrared light-emitting diodes.

The Model 480 PRO™ is FDA-cleared for use with the following indicated purposes:

  • Temporarily increasing local circulation
  • Temporarily reducing pain
  • Temporarily reducing stiffness
  • Temporarily reducing muscle spasm


The system allows clinicians to adjust energy output, treat multiple areas at once, and integrate therapy into existing clinical workflows.

How the Model 480 PRO™ Works

The Model 480 PRO™ delivers 890 nm monochromatic infrared energy via therapy pads placed on the skin. During treatment, patients typically experience a gentle therapeutic warmth in the treated area.

The Energy Control Dials on the control unit allow the clinician to set the energy level for each output channel. Light energy is delivered during the treatment time selected by the clinician, within the guidelines provided in the instructions for use.

Designed for Professional Use

The Model 480 PRO™ is engineered for clinics, therapy centers, and healthcare practices that want a flexible infrared light therapy system they can reliably integrate into patient care.

Key clinical features include:

  • Adjustable energy settings to match patient skin integrity and sensitivity
  • Eight separate therapy pads, each containing 60 infrared diodes
  • Ability to treat multiple locations on one patient (for example, foot and calf, elbow and hand)
  • Option to treat two patients at the same time when clinically appropriate
  • Hands-free application using attachment straps and application systems
  • Lightweight, portable control unit with carrying case

Indications and Intended Use

The Anodyne Therapy® System, Model 480 is intended for use:

  • To temporarily increase local circulation
  • To temporarily reduce pain
  • To temporarily reduce stiffness
  • To temporarily reduce muscle spasm

Clinical protocols may vary, but every treatment must follow the instructions for use and the precautions provided in the manual.

What's Included

  • Freedom 300™ main control unit
  • Foot therapy pad with attached sandal
  • Calf therapy pad with adjustable straps
  • Power supply
  • Carry bag
  • User instructions and support information

Key Features

  • Monochromatic infrared energy (MIRE™) at 890 nm
  • Eight flexible therapy pads (60 diodes per pad)
  • Independent energy controls and indicators
  • Hands-free treatment using approved attachment systems
  • Calibration and certifications to support regulatory compliance
  • Online staff training, clinical protocols, and support resources
  • Durable carrying case for transport and storage
  • Limited warranty (per current Anodyne Therapy® terms)

What’s Included

  • Model 480 PRO™ main control unit
  • Eight infrared therapy pads
  • Attachment straps and Velcro strips
  • Power cord and transformer
  • Carrying case
  • User instructions, clinical guidelines, and support contact information

Example Clinical Applications (By Indication Only)

The Model 480 PRO™ is designed for professional use where temporary:

  • Increase in local circulation is desired
  • Reduction of pain, stiffness, or muscle spasm is appropriate

Therapy pads may be placed on:

  • Feet and lower legs (using “T” configuration under the foot and pads on each side of the calf)
  • Hands and forearms
  • Soft tissue regions such as shoulders, neck, back, or joints
  • Areas proximal to open wounds (with a clear plastic barrier and without placing pads directly over dressings)

All use must follow the treatment time limits, energy settings, and pad placement guidance provided in the instructions for use.

Safety Information

The Model 480 PRO™ emits heat and may cause burns if used incorrectly. To reduce risk:

  • Never treat a given area for more than 45 minutes
  • Use lower energy settings for compromised skin integrity or reduced sensation
  • Avoid excessive pressure on therapy pads
  • Use caution over bony areas (ankles, knees, elbows, shins, tops of feet and hands)
  • Check the skin approximately every 10 minutes during treatment
  • Do not use topical heating agents, pain patches, or residual heating products under the pads
  • Do not use in or near water, or while the device or patient is wet

If the patient reports that the treatment feels too hot, or if excessive redness or discomfort occurs, discontinue treatment and follow the troubleshooting and reporting guidance.

Contraindications

Do not use Anodyne Therapy®:

  • Directly over or near the womb during pregnancy
  • Directly over an active cancer

The effects of treatment in these situations are unknown.

Infection Control

When treating multiple patients or an area with an open wound or lesion:

  • Always use a clear plastic barrier between the therapy pads and the skin
  • Replace the barrier between patients and discard after each use
  • Clean therapy pads and the control unit with an appropriate hospital-grade disinfectant according to facility protocol (without soaking or immersing components)

Care and Maintenance

To help maintain longevity and performance:

  • Do not drop the control unit or therapy pads
  • Do not pull therapy pads or cords from the unit by the cables
  • Do not wrap cords tightly around pads or the control unit
  • Do not saturate, soak, or autoclave any components
  • Hand wash attachment straps with mild detergent and air dry

All servicing and calibration should be performed by or under the direction of Anodyne Therapy, LLC. There are no user-serviceable internal parts.

Frequently Asked Questions

What does the Anodyne Therapy® Model 480 PRO™ do?

The Model 480 PRO™ is intended to temporarily increase local circulation and to temporarily reduce pain, stiffness, and muscle spasm.

Who is the Model 480 PRO™ designed for?

The Model 480 PRO™ is designed for use by healthcare professionals in clinical environments. It is not intended as a consumer home-use device.

How many therapy pads are included?

The system includes eight flexible therapy pads, each containing 60 infrared diodes.

Can I adjust the treatment intensity?

Yes. The clinician can set the energy level using the Energy Control Dials, within the guidelines provided in the instructions for use and considering skin integrity and sensitivity.

Can the Model 480 PRO™ treat more than one area at once?

Yes. The system can be used to treat multiple locations on the same patient, and in some cases may be configured to treat two patients at the same time, following appropriate clinical protocols.

How long is a typical treatment session?

Clinical treatment times generally range from 20 to 45 minutes per area, and a single area should not be treated for more than 45 minutes in one session. A minimum of four hours should separate treatment sessions on the same area.

Can it be used over implants or with pacemakers?

According to the instructions for use, the system may be used over metal implants, pins, and screws, and with patients who have pacemakers or defibrillators. Always follow facility protocols and consult device manuals when in doubt.

Is the Model 480 PRO™ noninvasive?

Yes. The system is a noninvasive infrared light therapy device applied externally to the skin.